symetrix_prism_12x12_dsp

Digital Signal Processor SYMETRIX Prism 12×12 Non Dante

SYMETRIX

อุปกรณ์ปรับแต่งสัญญาณเสียง SYMETRIX Prism 12×12 12-analog in and out, 128 Channel (64×64) Dante, OLED displays configuration and audio level, DSP Processing Identical to Radius / Edge / Solus NX, Delay Memory Identical to Radius / Edge / Solus NX

195,600 ฿

ราคาสินค้าไม่รวมภาษีมูลค่าเพิ่ม
หมวดหมู่: ป้ายกำกับ:

คำอธิบาย

SYMETRIX Prism 12×12  64×64 Multiple I/O Options without Dante

อุปกรณ์ปรับแต่งสัญญาณเสียง SYMETRIX Prism 12×12 12-analog in and out, 128 Channel (64×64) Dante, OLED displays configuration and audio level, DSP Processing Identical to Radius / Edge / Solus NX, Delay Memory Identical to Radius / Edge / Solus NX

The Prism family is the latest addition to the Symetrix line of Dante™ enabled DSPs. Symetrix uses Dante, a multi-channel digital media  networking technology, to interconnect multiple Symetrix DSPs, Symetrix I/O expanders, and select third-party Dante enabled devices. Prism  is ideally suited for applications requiring powerful, extremely cost effective advanced signal processing coupled with a standardized means for  future expansion.

Features:

  • 12 analog in and out, 64×64 Dante and powerful Symetrix DSP reduce overall system costs.
  • Ultra low latency Dante network audio protocol uses standard IT infrastructure.
  • Industry leading analog and A/D/D/A performance, 48 volt phantom mic power.
  • Configured using award winning Composer software. Controlled from ARC wall panels, ARC-WEB and third-party touchscreens. Embedded web server enables remote metering and diagnostics.
  • High-resolution graphic OLED displays configuration and audio levels.

Specifications

Analog Inputs

Number of Inputs Twelve (12) switchable balanced mic or line level.
Connectors 3.81 mm terminal blocks.
Nominal Input Level +4 dBu.
Maximum Input Level +23 dBu.
Mic Pre-amp gain 0, 12, 24, 44 or 54 dB switchable with ± 24 dB trim.
Mic Pre-amp EIN < -125dB with 150 ohm source impedance. 22.4 kHz BW.
CMRR > 79 dB @ 1 kHz, unity gain.
Input impedance 8k Ohms balanced, 4k Ohms unbalanced.
Phantom power (per input) +48 VDC, 10 mA maximum.
Dynamic range > 113 dB, A-weighted.
THD+Noise < -100 dB; 22.4 kHz BW, unweighted; 1 kHz @ +15 dBu with 0 dB gain. Course gain is set to +4dBu.
A to D Latency 0.28 mS.

Analog Outputs

Number of Outputs Twelve (12) balanced line level.
Connectors 3.81 mm terminal blocks.
Nominal Output Level +4 dBu with 20 dB of headroom.
Maximum Output Level +24 dBu (+22.8 dBu into a 2k Ohm minimum load).
Output Impedance 300 Ohms balanced, 150 Ohms unbalanced.
Dynamic Range > 117 dB, A-weighted.
THD+Noise < -97 dB; 22.4 kHz BW, unweighted; 1 kHz, 0 dB gain +8dBu output.
D to A Latency 0.60 mS.

System

Sampling Rate 48 kHz.
Frequency Response (A/D/A) 20 Hz – 20 kHz, ± 0.5 dB.
Dynamic Range (A/D/A) > 113 dB, A-weighted.
Channel Separation (A/D/A) > 110 dB @ 1 kHz, +24 dBu.
THD+Noise <-95 dB (22.4 kHz BW, un-weighted); 1 kHz @ +15 dBu with 0 dB gain.
Latency (A/D/A) 1.04 mS, inputs routed to outputs.
Processors 1 x Analog Devices SHARC 21489 @ 400 MHz SIMD.
Raw Processing Capacity 400 MIPS, 1.6 GFLOPS.
Delay Memory 174 mono seconds.
Analog control inputs 0-3.3 VDC.
Recommended External Control Potentiometer 10k Ohm, linear.
Logic Outputs Low (0V) when active, pulled high (5V) when inactive.
Logic Output Maximum External Power Supply Voltage 24 VDC.
Logic Output Maximum External Power Supply Current Sinking 50 mA.
Logic Output Maximum Output Current 10 mA.
RS-485 Serial I/O 38.4 kbaud (default) 8 data bits, 1 stop bit, no parity, no flow control. May be broken out of ARC port.
Ethernet Cable Standard CAT5e or CAT6, maximum device-to-device length = 100 meters.
Dante Cable Standard CAT6, maximum device-to-device length = 100 meters.
ARC Cable Standard CAT5, distance dependent upon load and number of devices. 8 Watts maximum power available.
Maximum Devices Per System 80 units per Site File.
Maximum Stored Presets 1000.

Mechanical Specifications

Space Required 1U (WDH: 18.91 in. x 9.5 in. x 1.72 in. / 48.02 cm x 24.13 cm x 4.37 cm). Depth does not include connector allowance. Allow at least 3 inch additional clearance for rear panel connections. Additional depth may be required depending upon your specific wiring and connections.
Electrical 24V 1.9A, 45W Maximum. Symetrix Part Number 12-0034. CUI part number SDI65-24-U-P5.
Ventilation Maximum recommended ambient operating temperature is 30 C / 86 F. Ensure that the left and right equipment sides are unobstructed (5.08 cm, 2 in minimum clearance). The ventilation should not be impeded by covering the ventilation openings with items such as newspapers, tablecloths, curtains, etc.
Certifications or Compliance Safety: UL 60065, cUL 60065, IEC 60065. EMC: “Class A” device (applies to all of the following) EN 55032, EN 55103-2, EN 61000-3-2, EN 61000-3-3, FCC Part 15, ICES-003. Environmental: RoHS.
Shipping Weight 8.5 lbs. (3.9 kg)

Downloads

ดาวน์โหลด Software & All Documents SYMETRIX Prism